Fluke Field Service Technicians Digital Multimeter
Model 115
  • Large white LED backlight to work in poorly lit areas
  • Resistance and continuity
  • Min/Max/Average to record signal fluctuations
  • CAT III 600 V safety rated

Safety conformance

All inputs are protected to CE, IEN61010-1 CAT III 600V. UL, CSA, TÜV listed and VDE.

Specifications
Maximum voltage between any terminal and earth ground
 600 V
Surge protection
 6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2
Display
Digital:  6,000 counts, updates 4 per second
Bar graph
 33 segments, updates 32 per second
Operating Temperature
 -10 °C to + 50 °C
Storage Temperature
 -40 °C to + 60 °C
Battery type
 9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery Life
 400 hours typical, without backlight
Accuracy Specifications
DC millivolts
Range:  600.0 mV
Resolution:  0.1 mV
Accuracy:  ± ([% of reading] + [counts]): 0.5% + 2
DC volts
Range/Resolution:  6.000 V / 0.001 V
Range/Resolution:  60.00 V / 0.01 V
Range/Resolution:  600.00 V / 0.1 V
Accuracy:  ± ([% of reading] + [counts]): 0.5% + 2
AC millivolts1 true-rms
Range:  600.0 mV
Resolution:  0.1 mV
Accuracy:  1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz)
AC volts1 true-rms
Range/Resolution:  6.000 V / 0.001 V
Range/Resolution:  60.00 V / 0.01 V
Range/Resolution:  600.0 V / 0.1 V
Accuracy:  1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz)
Continuity
Range:  600 Ω
Resolution:  1 Ω
Accuracy:  Beeper on < 20 Ω, off > 250 Ω; detectsopens or shorts of 500 μs or longer.
Ohms
Range/Resolution:  600.0 Ω / 0.1 Ω
Range/Resolution:  6.000 kΩ / 0.001 kΩ
Range/Resolution:  60.00 kΩ / 0.01 kΩ
Range/Resolution:  600.0 kΩ / 0.1 kΩ
Range/Resolution:  6.000 MΩ / 0.001 MΩ
Accuracy:  0.9 % + 1
Range/Resolution:  40.00 MΩ / 0.01 MΩ
Accuracy:  5 % + 2
Diode Test
Range/Resolution:  2.00 V / 0.001 V
Accuracy:  0.9% + 2
Capacitance
Range/Resolution:  1000 nF / 1 nF
Range/Resolution:  10.00 µF / 0.01 µF
Range/Resolution:  100.0 µF / 0.1 µF
Range/Resolution:  9999 µF / 1 µF
Range/Resolution:  100 µF to 1000 µF
Accuracy:  1.9% + 2
Range/Resolution:  > 1000 µF
Accuracy:  5% + 20%
Lo-Z Capacitance
Range:  1 nF to 500 µF
Accuracy:  10% + 2 typical
AC amps true-rms (45 Hz to 500Hz)
Range/Resolution:  6.000 A / 0.001 A
Range/Resolution:  10.00 A / 0.01 A
Accuracy:  1.5% + 3
 20 A overload for 30-seconds max
DC amps
Range/Resolution:  6.000 A / 0.001 A
Range/Resolution:  10.00 A / 0.01 A
Accuracy:  1.0% + 3
 20 A overload for 30-seconds max
Hz (V or A input)2

 

 

Notes:
1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F 
2) Frequency is ac coupled, 5Hz to 30 kHz for ac voltage

Mechanical & General Specifications
Size
 167 x 84 x 46 mm (6.57" x 3.31" x 1.82")
Weight
 550 g
Warranty
 3 years

 

Singapore (Head Office) :


Pacific Electronics (S) Pte Ltd
No. 1 Rochor Canal Road
#01-12  Sim Lim Square
Singapore 188504

Tel : (65) 6294 0851 / 6339 5884
Fax : (65) 6339 8454 / 6338 3609
Email : sales1@pacific-electronics.com

Showroom :
1 Rochor Canal Road #01-10/11
Sim Lim Square
Singapore 188504

Opening hours :
Monday ~ Friday : 9.30 a.m. to 6.00 p.m.
Saturday : 9.30 a.m. to 1.30 p.m.
Close on Sundays & Public Holidays

Malaysia (Branch Office in K.L.) :

Pacific Radio (M) Sdn Bhd
No. 80, Jalan Pasar Pudu,
55100 Kuala Lumpur,
West Malaysia

Tel : (60) 03 9221 8631 (6 Lines)
Fax : (60) 03 9221 8630
Email : sales1@pacificradio.com.my

Copyright 2013 All Rights Reserved. Pacific Electronics (S) Pte Ltd.